DIN21.FILTER to DIN32.FILTER

Description

This parameter sets the digital input filter configuration for channel x when followed with the values defined below. DINx.FILTER retrieves this information when not followed by data.

Value

Description

DINX.FILTER 0

The drive digital input channel detects all input signals with an input pulse width of ≥ 40 ns (no filtering applied).

DINX.FILTER 1

The drive digital input channel detects all input signals with an input pulse width of ≥ 10.24 µs, ± 0.64 µs (fast filter applied).

DINX.FILTER 2

The drive digital input channel detects all input signals with an input pulse width of ≥ 163 µs, ± 10.24 µs (standard filter applied).

DINX.FILTER 3

The drive digital input channel detects all input signals with an input pulse width of ≥ 2.62 ms, ± 0.16384 ms (slow filter applied).

General Information

Type

R/W Parameter

Units

N/A

Range

0 to 3

Default Value

2

Data Type

Integer

Start Version

M_01-03-07-000

Variants Supported

Supported by any AKD with extended IO.

Fieldbus

Index/Subindex

Is 64 bit? Attributes Signed?
Modbus 1310 DIN21.FILTER No 16 bit No
1322 DIN22.FILTER
1334 DIN23.FILTER
1346 DIN24.FILTER
1358 DIN25.FILTER
1370 DIN26.FILTER
1382 DIN27.FILTER
1394 DIN28.FILTER
1406 DIN29.FILTER
1418 DIN30.FILTER
1430 DIN31.FILTER
1442 DIN32.FILTER

Related Topics

Digitale Eingänge und Ausgänge